For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | SGR-1552W |
| Color | Light Yellow |
| Appearance | Liquid |
| Type | Reverse Osmosis (RO) Systems |
| Shelf Life | One Year |
| pH | 7.0 ±0.5 |
| Cleaning Method | Circulating Cleaning |
| Application | RO/NF/UF Systems |
| Specific Gravity | ≥1.10 |
| Transport Package | Blue Plastics Drum, White Plastics Drum |
| Specification | 25 kg/drum 1 ton/drum or as your requirement |
| Trademark | Scien Green |
| Origin | Jining City, Shandong Province, China |
| Production Capacity | 5000ton/Year |
| Package Size | 120.00cm * 100.00cm * 115.00cm |
| Package Gross Weight | 1054.000kg |
Calcium Sulfate Scale Membrane Cleaner: Solving RO/NF/UF System Downtime Crisis
For over a decade in industrial water treatment, we've witnessed countless production delays caused by calcium sulfate scaling on RO membranes. Research labs and manufacturing plants alike struggle with traditional cleaners that either require extended downtime or leave residual scale, compromising flux rates and contaminant rejection for weeks after cleaning. The frustration of unplanned maintenance disrupting R&D timelines or production schedules is all too familiar.
Efficient Circulation Cleaning for Critical Filtration Systems
Our Calcium Sulfate Scale Membrane Cleaner addresses these challenges with a specialized formulation designed for RO/NF/UF systems circulation cleaning. As a fast-response chemical service provider, we understand the urgency of minimizing equipment downtime—this cleaner's optimized pH (7.0 ±0.5) and high specific gravity (≥1.10) ensure effective scale dissolution without damaging delicate membrane materials, allowing return to service within minimal operational interruption.
Industrial Applications Across Water Treatment Sectors
This RO Membrane Cleaner finds critical use in pharmaceutical manufacturing, semiconductor production, and research laboratory water purification systems where membrane performance directly impacts product quality. The NF System Cleaner effectively removes calcium sulfate deposits in nanofiltration units processing industrial wastewater, while UF membrane cleaning applications benefit from its gentle yet powerful action on ultrafiltration systems in food and beverage processing.
Key Properties Ensuring Cleaning Efficacy
The liquid formulation (light yellow appearance) enables uniform circulation through membrane modules, ensuring complete contact with scale deposits. Its neutral pH profile prevents membrane hydrolysis that acidic cleaners often cause, while the high specific gravity ensures the solution maintains optimal contact time with vertical membrane surfaces. The one-year shelf life guarantees formulation stability from purchase to use, eliminating concerns about chemical degradation during storage.
Reliable Performance Minimizing Total Cost of Ownership
Using our RO System Calcium Sulfate Remover delivers measurable benefits compared to generic cleaners: reduced membrane replacement frequency, lower water consumption during rinse cycles, and fewer cleaning cycles required annually. Manufactured under strict quality control protocols, this NF Membrane Scale Cleaner Solution meets industrial standards for water treatment chemicals, ensuring consistent performance batch after batch—critical for maintaining process validation in regulated industries.
Our 10+ years of experience serving 50+ countries ensures every batch of UF System Circulation Cleaning Agent undergoes rigorous testing before release. With a production capacity of 5000 tons/year, we maintain stable supply chains even for large-scale industrial requirements. Factory direct supply eliminates middlemen markups, while our flexible production system can accommodate custom packaging from 25kg drums to 1-ton containers based on your operational needs.
Certificate of Analysis & Documentation
Every delivery includes a batch-specific Certificate of Analysis detailing key parameters such as pH, specific gravity, and appearance. Material Safety Data Sheets (MSDS) are provided for safe handling and regulatory compliance. For qualification purposes, additional product testing documentation can be requested to support your internal validation processes.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Order Process for Industrial Requirements
To ensure compatibility with your specific membrane system, we recommend starting with a sample evaluation. Our technical team can provide application guidance based on your system specifications and scaling severity. Once approved, orders are processed within 24 hours with delivery times ranging from 7-15 days, ensuring minimal disruption to your maintenance schedule.
Frequently Asked Questions
Q: What is the shelf life of this calcium sulfate scale cleaner?
A: The product has a shelf life of one year when stored properly in sealed containers away from direct sunlight and extreme temperatures.
Q: Can this cleaner be used for potable water systems or household appliances?
A: No, this product is FOR INDUSTRIAL AND LABORATORY RESEARCH USE ONLY. It is not intended for household use or treatment of drinking water.
Q: What documentation is provided with each order?
A: Every delivery includes a Certificate of Analysis (COA) for the specific batch and a Material Safety Data Sheet (MSDS) with handling instructions.
Q: Is custom packaging available beyond the standard 25kg and 1-ton drums?
A: Yes, we offer customized packaging options to meet specific operational requirements. Contact our sales team to discuss your needs.
Q: How does the cleaning method work for different membrane types?
A: The product is designed for circulation cleaning across RO, NF, and UF systems. Our technical team can provide specific circulation time and concentration recommendations based on your membrane type and fouling condition.