Keep power industry stainless steel and titanium pipes free from scale buildup and corrosion with our high-performance Scale and Corrosion Inhibitor, designed specifically for circulating cooling water systems. Its low phosphate formula (≤1.0% as PO₄³⁻) ensures compliance with strict industry standards while delivering reliable protection, so you can avoid costly downtime and maintain optimal system efficiency.
- White milky liquid formulation with ≥32.0% solid content for superior adhesion and long-lasting effectiveness
- Density ≥1.15 g/cm³ (20°C) ensures proper dispersion in cooling water without stratification
- Available in 25 kg, 200 kg, or 1 ton drums to fit both small-scale trials and full production needs
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | SGR0821W |
| Color | White Milky Liquid |
| Appearance | Liquid |
| Type | Industrial Circulating Water Treatment Agent |
| Product Name | Scale and Corrosion Inhibitor for Power Industry |
| Azole-Content (as C6h4nhn:N) % | No or ≥1.0 or ≥3.0 |
| Phosphate Content (as Po43-) % | ≤1.0 |
| Orthophosphate Content (as Po43-) % | ≤0.5 |
| Solid Content % | ≥ 32.0 |
| Density (20°C) G/Cm³ | ≥ 1.15 |
| Transport Package | Blue / White Plastics Drum |
| Specification | 25 kg/200 kg/1 ton drum |
| Trademark | Scien Green |
| Origin | Jining City, Shandong Province, China |
| Production Capacity | 15000 Ton/Year |
Scale and Corrosion Inhibitor for Power Industry Stainless Steel Titanium Pipes Circulating Cooling Water Treatment
In power plant operations, we’ve witnessed how inadequate water treatment leads to stainless steel pipe scaling that reduces heat transfer efficiency by 20-30% within months, while titanium pipe corrosion compromises system integrity and forces unplanned shutdowns. Traditional inhibitors often fail to balance scale prevention and corrosion control, especially in high-temperature circulating cooling systems where metal protection demands precise chemical formulation.
Advanced Formulation for Power Industry Metal Protection
Our Scale and Corrosion Inhibitor addresses these challenges through a balanced blend of corrosion inhibitors and scale dispersants specifically engineered for stainless steel and titanium pipes. With 10+ years serving power industry clients, we understand that maintaining azole content between 1.0-3.0% creates an effective protective film on metal surfaces, while strict phosphate control (≤1.0%) prevents calcium phosphate scaling—critical for maintaining cooling water system efficiency in power generation facilities.
Power Plant Cooling Water System Applications
This Circulating Cooling Water Agent finds primary application in coal-fired, natural gas, and nuclear power plant cooling loops, where it protects stainless steel heat exchangers, titanium condenser tubes, and piping systems from both general corrosion and localized pitting. Its liquid formulation ensures easy dosing and uniform dispersion, making it suitable for both open and closed recirculating systems operating under varying temperature and pH conditions.
Key Parameters for Reliable Performance
The solid content (≥32.0%) directly impacts the inhibitor’s effectiveness—higher solids mean lower dosage requirements and more economical treatment costs. Density (≥1.15 g/cm³ at 20°C) ensures proper mixing with cooling water without stratification, while orthophosphate content (≤0.5%) is critical for meeting environmental discharge standards. These specifications work in tandem to provide long-term protection without compromising system performance or regulatory compliance.
Benefits of Precision-Engineered Water Treatment
Using our Power Plant Cooling Water Inhibitor reduces maintenance costs by minimizing pipe scaling and corrosion-related failures, extending equipment lifespan by 3-5 years in typical applications. Unlike generic inhibitors, our formulation specifically targets stainless steel and titanium protection, eliminating the need for multiple treatment chemicals. With production capacity of 15,000 tons/year, we ensure consistent supply even for large power plant operations, supported by ISO 9001 quality management systems.
Our Quality Commitment
Every batch undergoes rigorous testing including azole content verification, density measurement, and solid content analysis, with complete Certificate of Analysis (COA) provided with each shipment. Our manufacturing facility in Shandong Province adheres to strict quality control protocols, from raw material inspection through final product testing. We maintain comprehensive batch records for 5 years, allowing full traceability and documentation support for your quality assurance needs.
Certificate of Analysis & Documentation
Each delivery includes a batch-specific COA with实测 values for all key parameters and safety data sheet (MSDS) with handling instructions. For critical applications, additional testing data can be provided upon request, including corrosion rate measurements and scale inhibition efficiency under simulated operating conditions.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Ordering Process
To place an order, contact our technical sales team with your specific cooling system parameters and treatment requirements. We recommend starting with a sample for compatibility testing, followed by full-scale implementation with our technical support. All orders include comprehensive documentation and post-delivery technical assistance to ensure optimal inhibitor performance.
Frequently Asked Questions
Q: What is the recommended storage temperature for this inhibitor?
A: The product should be stored in a cool, dry indoor environment. Avoid freezing or exposure to temperatures above 40°C for extended periods.
Q: Can this product be used in potable water systems?
A: No, this inhibitor is for industrial use only and not suitable for potable water applications.
Q: What documentation is provided with each shipment?
A: Each delivery includes a batch-specific Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS).
Q: Are custom packaging options available?
A: Standard packaging includes 25 kg, 200 kg, and 1 ton drums. Custom packaging may be available for large-volume orders.
Q: How is the inhibitor’s effectiveness measured?
A: Performance is verified through standard industry tests including corrosion coupon testing, scale inhibition efficiency, and pH stability studies, available upon request.