Accelerate your industrial circulating water treatment R&D with reliable corrosion protection using our Ethylene Glycol Corrosion Inhibitor. This 25kg supply of SGR 0814W ensures your systems stay protected without the wait, perfect for small-batch trials or urgent operational needs.
- Formulated as a colorless to light yellow transparent liquid with a solid content of ≥21%, it delivers consistent performance in industrial circulating water systems
- Maintains a pH of ≥9 in 1% aqueous solution, creating a stable environment to prevent corrosion and extend equipment lifespan
- Comes in a convenient plastic bucket, designed for easy handling and storage in laboratory or small-scale production settings
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Product Name | Ethylene Glycol Corrosion Inhibitor |
| Model NO. | SGR 0814W |
| Type | Industrial Circulating Water Treatment Agent |
| Appearance | Liquid |
| Color | Colorless to Light Yellow Transparent Liquid |
| Density (20°C) (G/Cm³) | ≥1.1 |
| pH (1% Aqueous Solution) | ≥9 |
| Solid Content (%) | ≥21% |
| Specification | 25kg |
| Transport Package | Plastic Bucket |
| Supplier | Factory Direct Supply |
| Trademark | SCIEN GREEN |
| Origin | Jining City, Shandong Province |
Overcoming Industrial Water System Corrosion Challenges with SGR 0814W Inhibitor
Industrial circulating water systems often face critical corrosion issues that lead to equipment failure, increased maintenance costs, and production downtime. In our 10+ years serving manufacturing plants and research facilities across 50+ countries, we’ve repeatedly seen how inconsistent inhibitor performance—whether due to substandard solid content or pH instability—can derail R&D trials and industrial operations alike. Traditional suppliers’ rigid minimum order quantities and slow delivery only exacerbate these problems, especially when urgent testing or small-scale production demands arise.
A Tailored Solution for Small-Batch and Urgent Requirements
Our SGR 0814W Ethylene Glycol Corrosion Inhibitor addresses these pain points through a specialized formulation designed for industrial circulating water treatment. As a factory-direct supplier with a flexible production system, we eliminate the middleman to deliver 25kg plastic bucket quantities—ideal for R&D trials or small-batch production—without compromising on quality. Our team responds to inquiries within 24 hours and ensures delivery within 7-15 days, a critical advantage when time-sensitive projects can’t wait for bulk order lead times.
Industrial Applications and Research Use Cases
This Circulating Water Inhibitor finds primary application in closed-loop industrial cooling systems, heat exchangers, and process water networks where ethylene glycol-based coolants are utilized. Its light yellow transparent liquid form allows for easy integration into existing treatment protocols, making it suitable for both laboratory-scale corrosion resistance testing and pilot-scale industrial trials. Research institutions can rely on its consistent composition to generate reproducible data on metal protection efficiency, while manufacturing facilities benefit from its ability to maintain system integrity during small-batch production runs.
Key Specifications Ensuring Performance Reliability
The technical parameters of SGR 0814W directly impact its corrosion inhibition efficacy. With a minimum solid content of 21%, the formulation provides sufficient active ingredients to form a protective film on metal surfaces, preventing electrochemical reactions that cause rust and pitting. The pH level (≥9 in 1% aqueous solution) ensures compatibility with ethylene glycol systems, avoiding acid-induced corrosion that can occur with improperly balanced inhibitors. Density (≥1.1 g/cm³ at 20°C) guarantees proper dispersion in water-glycol mixtures, ensuring uniform protection throughout the circulation system. These specifications are not arbitrary—they’re the result of rigorous testing to meet the “small batches, multiple varieties” demands of modern industrial R&D.
Quality Assurance Minimizing Operational Risks
Choosing a substandard corrosion inhibitor poses significant risks: inadequate metal protection leads to equipment failure, while inconsistent composition can invalidate research results or cause production defects. Our SGR 0814W adheres to strict quality control standards, with each batch undergoing comprehensive testing before release. Unlike suppliers offering “one-size-fits-all” solutions, our focus on small-batch customization ensures you receive an inhibitor tailored to your specific water chemistry and operational conditions. This precision translates to long-term cost savings by reducing maintenance needs and preventing unplanned downtime—critical factors for both research continuity and industrial productivity.
Our Commitment to Reliable Supply
With over a decade of experience serving 10,000+ industrial and research clients, our credibility is built on transparent quality control. Every 25kg plastic bucket of SGR 0814W comes with a detailed Certificate of Analysis (COA) documenting key parameters like solid content and pH. We maintain full production traceability, allowing clients to request batch-specific test data for validation. Our factory-direct model ensures supply stability even for fluctuating demand, supported by a dedicated customer service team available to address technical questions. Should any product fail to meet stated specifications, our no-questions-asked replacement policy underscores our confidence in consistent quality.
Certificate of Analysis & Documentation
Each order includes a batch-specific Certificate of Analysis (COA) with实测数据 for density, pH, solid content, and appearance. Material Safety Data Sheets (MSDS) are provided to ensure proper handling and storage compliance. For research institutions requiring detailed validation, additional test documentation can be requested by referencing your order number.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Order Process for Industrial and Research Needs
Initiate your order by submitting a request through our sales team, specifying your intended application and any special documentation requirements. For first-time users, we recommend confirming compatibility through small-scale testing, with sample quantities available upon request. Once specifications are confirmed, our production team begins manufacturing, with full logistics tracking provided until delivery. This straightforward process ensures minimal administrative delays, letting you focus on your core research or production goals.
Frequently Asked Questions
Q: What is the recommended shelf life of SGR 0814W?
A: When stored in unopened original packaging under recommended conditions, the product maintains stability for 12 months from the manufacturing date.
Q: Can this inhibitor be used in food or pharmaceutical production facilities?
A: No. This product is for industrial and laboratory research use only, and must not be used in processes involving direct contact with food, pharmaceuticals, or consumer products.
Q: What documentation is provided with each order?
A: Each shipment includes a Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS). Additional technical documentation can be requested prior to purchase.
Q: Is custom packaging available beyond the standard 25kg plastic bucket?
A: Yes, we offer customized packaging solutions for larger volume requirements. Contact our sales team to discuss your specific needs.
Q: How is the product’s corrosion inhibition efficiency verified?
A: Each batch undergoes electrochemical testing and immersion corrosion trials following industry standard protocols, with results documented in the COA.