Streamline your boiler and carbon steel cleaning process with EDTA low temperature corrosion inhibitor, designed to deliver high-performance protection at 90-95°C without compromising on purity. Achieve efficient, residue-free cleaning while safeguarding your equipment from corrosion, ensuring your R&D or small-batch production stays on schedule with reliable results.
- 98% high purity formula ensures optimal reactivity, reducing the need for excess dosing and minimizing waste
- Liquid form with pH ≥9.0 provides stable performance in low-temperature cleaning cycles, ideal for precision applications
- One-year shelf life and flexible packaging options (25kg/drum or 1ton/drum) accommodate both urgent trials and ongoing needs
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | SGR-0408W |
| Color | Reddish Brown |
| Appearance | Liquid |
| Type | Corrosion Inhibitor |
| Shelf Life | One Year |
| Supplier | Factory Direct Supply |
| pH | ≥9.0 |
| Density (20°C, G/Cm³) | 1.0±0.05 |
| Active Content | ≥ 98% |
| Transport Package | Blue Plastics Drum, White Plastics Drum |
| Specification | 25 kg/drum, 1 ton/drum or as your requirement |
| Trademark | Scien Green |
| Origin | Jining City, Shandong Province, China |
| HS Code | 2931900090 |
| Production Capacity | 3000ton/Year |
EDTA Corrosion Inhibitor for Boiler & Carbon Steel: Solving Low-Temperature Cleaning Challenges at 90-95°C
We’ve seen countless research labs and manufacturing facilities struggle with corrosion during low-temperature boiler cleaning—either due to subpar inhibitors that fail at 90-95°C or suppliers enforcing minimum order quantities that leave small-batch users overstocked. Inconsistent active content in generic inhibitors often leads to unexpected metal pitting, while delayed deliveries have derailed many critical R&D timelines.
Stable Performance in Low-Temperature Boiler Systems
Our EDTA Low Temperature Cleaning Corrosion Inhibitor addresses these pain points with a high-purity formula designed specifically for 90-95°C operations. With ≥98% active content and pH stability ≥9.0, it provides reliable protection for carbon steel components without the batch-to-batch variability that plagues generic alternatives. Our flexible production system supports both small-batch trials (starting from 25kg) and large-scale orders, ensuring researchers and manufacturers get exactly what they need when they need it.
Industrial Applications for Boiler & Carbon Steel Maintenance
This boiler carbon steel cleaning inhibitor is widely used in industrial boiler systems, power plant maintenance, and metal surface treatment processes where low-temperature cleaning is required. Its liquid form allows easy integration into existing cleaning protocols, while the reddish brown color provides visual confirmation of proper dispersion. Typical applications include descaling operations, pre-commissioning cleaning, and routine maintenance of carbon steel pipelines and heat exchangers.
Key Specifications for Reliable Corrosion Protection
The ≥98% active content ensures minimal dilution requirements, reducing both material costs and waste generation. The controlled density of 1.0±0.05 g/cm³ at 20°C guarantees consistent mixing ratios, while the alkaline pH (≥9.0) enhances EDTA’s chelating efficiency in low-temperature environments. These specifications work together to prevent hydrogen embrittlement and metal dissolution, critical factors in maintaining boiler integrity during cleaning cycles. Unlike standard inhibitors, our formula maintains stability even when exposed to varying water hardness levels.
Benefits of High-Purity Low Temperature Inhibitor
Choosing a high-quality EDTA inhibitor directly impacts operational costs and safety. Inferior products with low active content may require higher dosages, increasing expenses and environmental impact, while impurities can cause secondary fouling or equipment damage. Our inhibitor meets strict industrial standards, supporting compliance with ISO 9001 quality management systems. The one-year shelf life ensures long-term usability, reducing inventory turnover pressure for research facilities and small-scale producers.
Quality Assurance You Can Verify
Every batch of our EDTA corrosion inhibitor undergoes rigorous testing, including active content analysis, pH measurement, and density verification. We provide a detailed Certificate of Analysis (COA) with each shipment, documenting all critical parameters. Our production facility in Shandong Province maintains a 3000-ton annual capacity, ensuring stable supply even during peak demand periods. If specifications do not match the COA, we offer unconditional replacement or refund—no questions asked.
Certificate of Analysis & Documentation
Each delivery includes a batch-specific COA and MSDS, providing comprehensive safety and handling information. For critical applications, additional testing data can be requested, including stability studies and compatibility reports with common cleaning agents. All documentation complies with international shipping standards, facilitating customs clearance for export to 50+ countries.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Simple Ordering Process for Your Requirements
Initiate your order by submitting a request through our contact channels, specifying your required quantity and packaging preferences (25kg drum, 1 ton drum, or custom). We provide technical support to help determine optimal dosage rates for your specific application. Sample evaluations are available for first-time users, with full-scale production typically delivered within 7-15 days of order confirmation.
Frequently Asked Questions
Q: What is the shelf life of this EDTA corrosion inhibitor?
A: The product has a shelf life of one year when stored in sealed containers under recommended conditions.
Q: Can this inhibitor be used for food or pharmaceutical applications?
A: No, this product is for industrial and laboratory research use only, not for direct human consumption or therapeutic purposes.
Q: What documentation is provided with each shipment?
A: Each order includes a Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS).
Q: Is custom packaging available beyond the standard options?
A: Yes, packaging can be customized according to specific requirements; contact our sales team for details.
Q: How is the product’s purity verified?
A: Purity is confirmed through active content analysis, with results documented in the batch-specific COA provided with each shipment.