Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | SGR-0901W |
| Color | Light Yellow |
| Appearance | Liquid |
| Type | Industrial Circulating Water Treatment Agent |
| Shelf Life | One Year |
| Solid Content % | ≥21.0 |
| Density (20°C) g/cm3 | ≥1.10 |
| pH (1% Aqueous Solution) | ≤4.5 |
| Transport Package | Blue Plastics Drum, White Plastics Drum |
| Specification | 25 kg/drum 1 ton/drum or as your requirement |
| Origin | Jining City, Shandong Province, China |
| HS Code | 2917190090 |
SGR-0901W: Solving Near Zero Discharge Challenges in Sewage Reuse Cooling Systems
For over a decade, we've witnessed countless industrial clients struggle with cooling system inefficiencies when implementing sewage reuse—excessive scaling blocking heat transfer, corrosion eating through pipes, and traditional inhibitors failing to meet near zero discharge requirements. Research labs testing water treatment protocols face similar frustrations: inconsistent inhibitor performance derailing months of R&D progress.
A Tailored Solution for Sewage Reuse Open Loop Systems
Our Sewage Reuse Open Loop Cooling Water Corrosion and Scale Inhibitor (SGR-0901W) directly addresses these pain points. As a small-batch chemical specialist serving 50+ countries, we understand the critical need for reliable formulations that perform under the unique conditions of reclaimed water. This industrial water treatment agent delivers exceptional corrosion and scale inhibition even in high TDS environments, supporting near zero discharge operations without compromising system efficiency.
Industrial Applications & Research Versatility
This product finds extensive use in power plants, chemical processing facilities, and manufacturing plants implementing sewage reuse open loop cooling systems. Research institutions utilize it to develop and validate water treatment protocols for sustainable industrial water management. Its specialized formulation makes it ideal for pilot-scale trials and full-scale industrial deployment, providing consistent results across both R&D and production environments.
Key Specifications Explained
The 21.0% minimum solid content ensures effective inhibition at lower dosage rates, reducing overall treatment costs while maintaining performance. With a density of ≥1.10 g/cm³ at 20°C, the product exhibits excellent mixing properties, ensuring uniform distribution in cooling water systems. The pH ≤4.5 (1% aqueous solution) allows for stable performance across varying water chemistries commonly found in reclaimed water sources. These specifications work in tandem to provide reliable scale prevention and corrosion protection, critical factors in maintaining system integrity during near zero discharge operations.
Benefits of Reliable Water Treatment Chemistry
Choosing a high-quality sewage reuse corrosion inhibitor like SGR-0901W translates to significant operational benefits: reduced maintenance costs from minimized scaling and corrosion, extended equipment lifespan, and uninterrupted production cycles. Unlike inferior products that may contain harmful impurities or inconsistent active ingredient levels, our formulation meets strict industrial standards, ensuring compliance with environmental regulations for near zero discharge systems. The result is a lower total cost of ownership and enhanced sustainability for your water treatment operations.
Our Commitment to Quality Assurance
Every batch of SGR-0901W undergoes rigorous quality control testing, including analysis of active ingredient content, density, and pH levels. We maintain a production capacity of 15,000 tons/year, ensuring consistent supply even for large-scale operations. As a factory direct supplier with 10+ years of experience, we stand behind our products—offering comprehensive technical support and documentation to ensure optimal performance in your specific application. Our commitment to quality has earned the trust of over 10,000 industrial customers and research institutions worldwide.
Certificate of Analysis & Documentation
Each shipment of SGR-0901W includes a Certificate of Analysis (COA) specific to that batch, detailing all tested parameters. Material Safety Data Sheets (MSDS) are provided with every order, containing comprehensive safety and handling information. For research purposes requiring detailed characterization, additional technical documentation can be made available upon request, supporting your validation and compliance efforts.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Ordering Process
To place an order for SGR-0901W, simply contact our technical sales team with your specific requirements, including desired quantity and packaging preferences. We offer flexible packaging options (25 kg/drum, 1 ton/drum, or custom specifications) to suit both small-batch research needs and large-scale industrial applications. Our team can provide technical guidance to ensure optimal dosage and application methods for your unique system conditions.
Frequently Asked Questions
Q: What is the shelf life of SGR-0901W?
A: The product has a shelf life of one year when stored properly in sealed containers away from direct sunlight and extreme temperatures.
Q: Can this inhibitor be used in food or pharmaceutical applications?
A: No, this product is for industrial and laboratory research use only and should not be used in food, pharmaceutical, or direct human consumption applications.
Q: What documentation is provided with each order?
A: Each shipment includes a Certificate of Analysis (COA) for the specific batch and a Material Safety Data Sheet (MSDS).
Q: Is custom packaging available?
A: Yes, packaging can be customized to meet specific requirements beyond the standard 25 kg/drum and 1 ton/drum options.
Q: How is the effectiveness of the inhibitor determined?
A: Effectiveness is verified through standard corrosion and scale inhibition testing protocols, with results provided in the product's technical documentation.