For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| EINECS | Compound |
| Acid-Base Property | Alkaline Surface Disposal Agent |
| Environmental Protection | Yes |
| Color | Light Yellow |
| Appearance | Liquid |
| Type | Industrial Circulating Water Treatment Agent |
| Product Name | Reverse Osmosis Membrane Cleaner (Alkaline) |
| pH | 11.5-12 |
| Storage | Shady and Ventilated |
| Transport Package | Blue / White Plastics Drum |
| Specification | 25 kg/200 kg/1 ton drum |
| Trademark | GIDINEW |
| Origin | Jining City, Shandong Province, China |
| Production Capacity | 15000 Ton/Year |
| Package Size | 31.00cm * 26.00cm * 42.00cm |
| Package Gross Weight | 26.000kg |
Calcium Sulfate Scaling Challenges in RO Water Reuse Systems? Meet Our Special RO Membrane Scale Inhibitor
For over a decade supporting water treatment facilities across 50+ countries, we've witnessed how calcium sulfate scaling in alkaline water reuse systems can cripple RO membrane performance—reducing flux by 30% within months and forcing costly cleaning cycles. Traditional inhibitors often fail under high pH conditions (11.5-12), leading to unplanned downtime that delays research trials and industrial production schedules.
Alkaline-Resistant Formula for Uninterrupted RO System Operation
Our Special RO Membrane Scale Inhibitor addresses this critical pain point with a proprietary alkaline formula engineered to stabilize calcium sulfate solubility even in pH 11.5-12 environments. As a fast-response chemical service provider, we've optimized our production to deliver small-batch orders within 7-15 days, ensuring laboratories and pilot plants maintain continuous operation without overstocking.
Industrial Applications in Water Reuse Systems
This Water Reuse Scale Inhibitor finds essential application in municipal wastewater reuse facilities, industrial process water recycling, and research laboratories studying high-salinity water treatment. Its liquid form allows precise dosing in membrane systems, making it ideal for both bench-scale experiments and full-scale industrial circulating water treatment processes.
Key Specifications That Ensure Performance
The alkaline pH (11.5-12) of this RO Scale Inhibitor is critical for compatibility with high-alkalinity water reuse streams, preventing acid-base reactions that could compromise membrane integrity. Its light yellow liquid appearance allows for easy visual monitoring of dosing concentrations, while the 25kg-1ton drum specifications accommodate both small research trials and large industrial deployments. The product's environmental protection certification ensures compliance with strict discharge regulations in water treatment applications.
Reliable Performance vs. Costly Scaling Consequences
Using a substandard Calcium Sulfate Inhibitor can lead to membrane fouling that requires chemical cleaning every 2-3 months, increasing operational costs by 40% annually. Our formulation, backed by ISO 9001 quality management systems, maintains membrane efficiency for 6+ months between cleanings. With a production capacity of 15,000 tons/year, we guarantee consistent supply to prevent the production delays that occur when scaling inhibitors are unavailable.
Our commitment to quality is verified through comprehensive testing protocols, including solubility testing under alkaline conditions and scale inhibition efficiency measurements using standard NACE TM0374 procedures. Each batch is accompanied by a Certificate of Analysis detailing pH, appearance, and inhibitor concentration. We offer technical support from our team of chemical engineers with 10+ years in water treatment chemistry, and stand behind every order with a specification guarantee—if our Alkaline Formula RO Scale Inhibitor doesn't meet stated parameters, we'll replace it at no cost.
Certificate of Analysis & Documentation
Every shipment includes a batch-specific Certificate of Analysis and MSDS, with detailed test data available upon request. For research institutions requiring full traceability, we can provide raw material sourcing documentation and stability testing records for the past 36 months.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Order Process for Your Water Treatment Needs
Initiate your order by submitting technical requirements through our online inquiry system, including desired quantity and delivery timeline. We provide formal quotations within 24 hours, and can arrange sample shipments for performance evaluation in your specific water matrix. Once specifications are confirmed, our flexible production system ensures on-time delivery with full logistics tracking.
Frequently Asked Questions
Q: What is the recommended shelf life of this RO Membrane Calcium Sulfate Inhibitor?
A: When stored in unopened original containers under shady and ventilated conditions, the product maintains stability for 12 months from the manufacturing date.
Q: Is this product suitable for potable water treatment applications?
A: No, this product is intended for industrial and laboratory research use only, not for direct human consumption or household applications.
Q: What documentation is provided with each order?
A: Every shipment includes a Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS). Additional technical documents can be requested prior to purchase.
Q: Can the packaging size be customized for small laboratory orders?
A: Yes, we offer flexible packaging options including 25kg drums suitable for laboratory-scale applications, with custom labeling available for research institutions.
Q: How is the effectiveness of the scale inhibitor determined?
A: Performance is validated through standard test methods measuring calcium sulfate nucleation inhibition and threshold scaling concentration, with detailed protocols available in the product technical data sheet.